← MAX-MV series overview · Explore all 10 selection guides
01 · Product overview
The drive must fit the compressor process.
MAX-MV controls large compressor motors in mechanical vapour recompression, chemical processing, gas and industrial utilities. Suitable configurations support induction, synchronous and permanent-magnet synchronous motors, with the control mode and feedback selected around the machine requirements.
A compressor proposal must distinguish continuous variable-speed operation from a variable-frequency starting and transfer duty. The permitted speed/torque envelope, lubrication, seal systems, process interlocks and transient behaviour remain central to the package. INOMAX works from the compressor OEM’s operating requirements when defining the electrical solution.
02 · Rating and cabinet selection
Power, voltage and current selection
Match the motor nameplate current, overload duty and site derating before confirming a model. The filters below help you compare the listed selections; final cabinet and option details are agreed for the project.
7 reference selections
No matching selection in this table. Send your motor data for engineering review.
Dimensions exclude top fans, bypass additions and service clearances. At 6.6 kV from 2,800 kW and 11 kV from 4,500 kW, add an 800 mm current-limiting cabinet with matching depth and height. Use the approved project drawing for the complete installation.
03 · Application fit
Application requirements that shape the package
MVR steam compression
Evaporation and wastewater-resource recovery systems where steam-compressor speed is coordinated with the process demand.
Centrifugal process compressors
Rich gas, air and other process duties. Coordinate speed control with the compressor map and the separate anti-surge/protection system.
Screw and other compressor packages
Evaluate the actual torque characteristic, unloading arrangement, lubrication and motor technology. Different compressor types must not share an assumed control envelope.
04 · Integration and options
Functions, accessories and engineering decisions
Start with the approved compressor map
Obtain the minimum continuous speed, maximum speed, torque demand, acceleration limits and prohibited operating regions. Motor voltage and drive frequency capability do not independently authorize operation outside the compressor manufacturer’s limits.
Preserve process-protection responsibility
Define how the drive receives permissives and trips from lubrication, seal gas, vibration and temperature systems. For centrifugal compressors, agree the speed interface with anti-surge control; a drive’s built-in PID should not be treated as a complete anti-surge system.
Coordinate synchronous-motor operation
Synchronous and permanent-magnet configurations require motor-specific data. Where applicable, include excitation, feedback, starting sequence and the requirements for transfer to the supply. Confirm the final motor/duty suffix combination in the technical proposal.
Specify continuity for critical service
Discuss reduced-output operation, redundant controllers, a standby drive and planned shutdown access. A controller backup, cell bypass and a complete standby drive protect different parts of the system. The accepted fault response should be tested against the process requirement.
Define the equipment scope
| Configuration item | What to agree |
|---|---|
| Motor control and feedback | Motor technology, control mode and encoder interface where required |
| Bypass / isolation | Manual or automatic line bypass, isolation and switching interlocks; selected for the process |
| Control integration | Standard Modbus RTU / I/O; optional PROFIBUS DP or exact TCP/IP arrangement |
| Continuity options | Cell-bypass strategy, controller redundancy or standby drive as project-selected |
| Service package | Spare cells, fans, boards, commissioning and training scope |
05 · Electrical performance
Performance for a defined operating duty
| Performance item | Selection basis |
|---|---|
| Motor-control modes | V/F; V/F with feedback; sensorless vector; closed-loop vector |
| Overload capability | 120% for 120 s; 150% for 5 s, checked against selected configuration and duty |
| Frequency resolution | 0.01 Hz; resolution is distinct from motor-speed accuracy |
| Acceleration / deceleration | 0.1–3,600 s; set within motor and process limits |
| Inverter efficiency | 98.5%; excludes the phase-shifting transformer |
| Power factor | ≥0.96 at the specified operating conditions |
| Harmonic performance | THD ≤4% for 3–4.16 kV; ≤2% for 6–13.8 kV. Confirm measurement point, loading and network conditions. |
Confirm performance at the required motor duty, supply conditions and cooling arrangement. For regenerative or braking loads, specify the operating cycle so a suitable two- or four-quadrant power stage can be selected.
06 · Technical data
Installation, environment and maintenance
| Item | Requirement / configuration |
|---|---|
| Operating temperature | −10 to +40°C; higher temperature requires an approved cooling and derating plan |
| Humidity | 20–90% RH, non-condensing, as the installation basis; confirm higher-humidity configurations |
| Altitude | Provide the site elevation; above 1,000 m, review insulation, cooling and derating for the selected configuration |
| Storage | −40 to +70°C; dry, protected storage without condensation or outdoor exposure |
| Cooling and enclosure | Forced air or water cooling; IP31 standard, IP42 optional, custom IP54 |
| Control supply | 220 V AC, 3 kVA, 50/60 Hz; optional DC supply by project arrangement |
| Control interfaces | 3 analog inputs / 4 analog outputs; 8 digital inputs / 5 digital outputs; RS485 / Modbus RTU standard |
| Installation | Indoor electrical room; no explosive/corrosive gases, conductive dust or oil mist; keep cooling and service access clear |
Plan safe service access, delivery openings, foundation loading and separate power/control cable routes. Inspection intervals and replacement work follow the installed equipment manual and the site maintenance plan.
07 · Supplier and configuration comparison
Compare complete proposals on the same basis
| Comparison point | What to check |
|---|---|
| Operating duty | Compare continuous speed control separately from starting-and-transfer systems. |
| Motor control | Use the same motor technology, current, speed range and torque profile. |
| Process interfaces | Include anti-surge coordination, auxiliary permissives and protective trips. |
| Acceptance | Agree the motor/load test arrangement, control sequence and documented performance criteria. |
Ask each supplier to identify inclusions, exclusions and deviations. The selected rating, options, installation work, acceptance test and service responsibilities should be clear before comparing the final price.
08 · Customer applications
Relevant industrial project experience
Jiangsu Jurong Chemical
10 kV · 4,000 kW
A MAX-MV-100-4000 drive provided variable-speed control for a rich-gas compressor.
Yili Chuanning Biotechnology
10 kV · 8,000 kW
The Xi’an Shaangu Power steam-compressor project selected MAX-MV-100-8000 for the effluent-treatment and MVR evaporation system.

Discuss a comparable configuration with INOMAX. The motor, equipment scope and operating conditions are assessed separately for each project.
Practical project FAQ
Questions to resolve before ordering
6 questions
Does INOMAX have an 8 MW MVR compressor reference?
A MAX-MV-100-8000 drive was selected for the Xi’an Shaangu Power steam-compressor project serving Yili Chuanning Biotechnology’s secondary-settlement effluent treatment and MVR evaporation system. The reference supports application discussion; it does not define the rating or performance of every MVR package.
Can MAX-MV be used for a rich-gas compressor?
The Jiangsu Jurong Chemical reference used a MAX-MV-100-4000 drive for rich-gas compressor variable-speed control. A new project requires the compressor operating map, motor data, protection interfaces and site conditions to be reviewed.
Is compressor anti-surge control built into the VFD?
The compressor protection and anti-surge responsibilities must be defined with the OEM. MAX-MV can accept process references and interlocks, but its general PID function should not be specified as a complete centrifugal-compressor anti-surge system without an approved application design.
Can the motor run above its base speed?
Only within the approved motor and compressor limits. Review available torque, field-weakening behaviour, mechanical critical speeds, bearings and process limits. The maximum drive frequency setting is not permission to overspeed the equipment.
What is the difference between a compressor VFD and a variable-frequency soft-start supply?
A VFD can provide continuous variable-speed operation. A starting supply may accelerate the motor and transfer it to line operation through an engineered switching sequence. Specify which duty is required so the power stage, switching and control package are correctly scoped.
What should a compressor OEM include in the technical enquiry?
Provide the motor data, compressor type and map, permitted speed range, start/unload sequence, lubrication and protection requirements, control interface and continuity target. Add site voltage, cooling conditions, FAT requirements and the delivery plan.
No matching question. Ask our application team.
Technical resources
Catalog, manual & project support
MAX-MV catalog
Ratings, dimensions, features and configuration options.
MAX-MV user manual
Installation, operation, control settings and maintenance.
Project-specific documents
Contact INOMAX for project records, drawings, certificates and test reports matched to your application.
09 · Start the conversation
Let’s define your next MAX-MV project.
Discuss Your Compressor Drive Package
Send the compressor operating envelope, motor data and control sequence for an application-specific proposal.
Email: info@inomaxtechnology.com
Build your local MAX-MV business
Discuss the industries you serve, application-engineering support, training, commissioning and spare-parts planning. Commercial and service arrangements are defined for your market and projects.