MAX510 VFDs for precise motor control and easier integration.
0.75–710 kW Normal Duty, with 220–240 V and 380–480 V selections. A flexible drive platform for distributors, machine builders and system integrators—from sensorless control to encoder feedback and industrial networks.
Simple enquiry • Product multi-select • 24-month warranty

Select by supply, current and duty.
Match the supply first, then check motor current, load cycle and the required overload. The table combines order codes, G-duty output current and frame dimensions for an initial engineering selection.
| Input supply | Listed motor power | Output current / motor voltage |
|---|---|---|
| 3-phase 380–480 V · 4T | G: 0.75–710 kW; P: 1.5–800 kW | G current: 2.5–1260 A; three-phase 380–480 V-class motor |
| 1-phase 220–240 V · 2S | G: 0.75–18.5 kW | 4–70 A; three-phase 220–240 V-class motor |
| 3-phase 220–240 V · 2T | G: 0.75–18.5 kW | 4–70 A; three-phase 220–240 V-class motor |
| G kW | P kW | Order code | G output A | W × H × D, mm | Net kg |
|---|---|---|---|---|---|
| 0.75 | 1.5 | MAX510-4T-0.75GB/1.5PB | 2.5 | 76 × 200 × 160 | 1.2 |
| 1.5 | 2.2 | MAX510-4T-1.5GB/2.2PB | 3.8 | 76 × 200 × 160 | 1.2 |
| 2.2 | 3.7 | MAX510-4T-2.2GB/3.7PB | 5.1 | 76 × 200 × 160 | 1.2 |
| 3.7 | 5.5 | MAX510-4T-3.7GB/5.5PB | 9 | 76 × 200 × 160 | 1.2 |
| 5.5 | 7.5 | MAX510-4T-5.5GB/7.5PB | 13 | 100 × 242 × 165 | 2.3 |
| 7.5 | 11 | MAX510-4T-7.5GB/11PB | 17 | 100 × 242 × 165 | 2.3 |
| 11 | 15 | MAX510-4T-11GB/15PB | 25 | 116 × 320 × 185 | 3.5 |
| 15 | 18.5 | MAX510-4T-15GB/18.5PB | 32 | 142 × 383 × 227 | 5.5 |
| 18.5 | 22 | MAX510-4T-18.5GB/22PB | 37 | 142 × 383 × 227 | 5.5 |
| 22 | 30 | MAX510-4T-22GB/30PB | 45 | 142 × 383 × 227 | 5.5 |
| 30 | 37 | MAX510-4T-30G/37P | 60 | 173 × 430 × 230 | 13.3 |
| 37 | 45 | MAX510-4T-37G/45P | 75 | 173 × 430 × 230 | 13.3 |
| 45 | 55 | MAX510-4T-45G/55P | 91 | 242 × 560 × 310 | 26 |
| 55 | 75 | MAX510-4T-55G/75P | 112 | 242 × 560 × 310 | 26 |
| 75 | 90 | MAX510-4T-75G/90P | 150 | 242 × 560 × 310 | 26 |
| 90 | 110 | MAX510-4T-90G/110P | 176 | 270 × 638 × 350 | 36 |
| 110 | 132 | MAX510-4T-110G/132P | 210 | 270 × 638 × 350 | 36 |
| 132 | 160 | MAX510-4T-132G/160P-L | 253 | 349 × 738 × 403 | 65 |
| 160 | 185 | MAX510-4T-160G/185P-L | 304 | 349 × 738 × 403 | 65 |
| 185 | 200 | MAX510-4T-185G/200P-L | 326 | 360 × 940 × 480 | 90 |
| 200 | 220 | MAX510-4T-200G/220P-L | 377 | 360 × 940 × 480 | 90 |
| 220 | 250 | MAX510-4T-220G/250P-L | 426 | 360 × 940 × 480 | 90 |
| 250 | 280 | MAX510-4T-250G/280P-L | 465 | 369 × 1141 × 550 | 130 |
| 280 | 315 | MAX510-4T-280G/315P-L | 520 | 369 × 1141 × 550 | 130 |
| 315 | 355 | MAX510-4T-315G/355P-L | 585 | 400 × 1250 × 550 | 209 |
| 355 | 400 | MAX510-4T-355G/400P-L | 650 | 400 × 1250 × 550 | 209 |
| 400 | 450 | MAX510-4T-400G/450P-L | 725 | 400 × 1250 × 550 | 209 |
| 450 | 500 | MAX510-4T-450G/500P-L | 820 | 460 × 1400 × 544 | 230 |
| 500 | 560 | MAX510-4T-500G/560P-L | 860 | 460 × 1400 × 544 | 230 |
| 560 | 630 | MAX510-4T-560G/630P-L | 950 | 460 × 1400 × 544 | 230 |
| 630 | 710 | MAX510-4T-630G/710P-I | 1100 | 850 × 1800 × 700 | 475 |
| 710 | 800 | MAX510-4T-710G/800P-I | 1260 | 850 × 1800 × 700 | 475 |
| 0.75 | — | MAX510-2S-0.75GB | 4 | 76 × 200 × 160 | 1.2 |
| 1.5 | — | MAX510-2S-1.5GB | 7 | 76 × 200 × 160 | 1.2 |
| 2.2 | — | MAX510-2S-2.2GB | 9.6 | 76 × 200 × 160 | 1.2 |
| 3.7 | — | MAX510-2S-3.7GB | 16 | 100 × 242 × 165 | 2.3 |
| 5.5 | — | MAX510-2S-5.5GB | 20 | 100 × 242 × 165 | 2.3 |
| 7.5 | — | MAX510-2S-7.5GB | 30 | 142 × 383 × 227 | 5.5 |
| 11 | — | MAX510-2S-11GB | 42 | 142 × 383 × 227 | 5.5 |
| 15 | — | MAX510-2S-15G | 55 | 173 × 430 × 230 | 13.3 |
| 18.5 | — | MAX510-2S-18.5G | 70 | 173 × 430 × 230 | 13.3 |
| 0.75 | — | MAX510-2T-0.75GB | 4 | 76 × 200 × 160 | 1.2 |
| 1.5 | — | MAX510-2T-1.5GB | 7 | 76 × 200 × 160 | 1.2 |
| 2.2 | — | MAX510-2T-2.2GB | 9.6 | 76 × 200 × 160 | 1.2 |
| 3.7 | — | MAX510-2T-3.7GB | 16 | 100 × 242 × 165 | 2.3 |
| 5.5 | — | MAX510-2T-5.5GB | 20 | 100 × 242 × 165 | 2.3 |
| 7.5 | — | MAX510-2T-7.5GB | 30 | 142 × 383 × 227 | 5.5 |
| 11 | — | MAX510-2T-11GB | 42 | 142 × 383 × 227 | 5.5 |
| 15 | — | MAX510-2T-15G | 55 | 173 × 430 × 230 | 13.3 |
| 18.5 | — | MAX510-2T-18.5G | 70 | 173 × 430 × 230 | 13.3 |
No listed model matches this filter. Change the power band or request application sizing.
G = Normal Duty; P = Light Duty. Dimensions are overall frame dimensions; mounting centres and clearances are in the drawings. B = built-in braking designation; L = DC reactor; I = AC input reactor. Confirm the actual braking option when ordering. The 630/710 kW cabinet models include an input AC reactor and are supplied without an air circuit breaker.
Choose the control and communication you need.
V/f control
Frequency-based operation for applications that do not require vector torque control.
Sensorless vector
Speed and torque regulation without encoder wiring. Useful for general industrial machinery and variable-speed processes.
Feedback vector
Encoder-based regulation for demanding low-speed operation. Select the feedback card and motor configuration together.
| Performance | SVC: sensorless vector | FVC: feedback vector |
|---|---|---|
| Speed regulation range | 1:200 | 1:1000 |
| Speed accuracy | 0.5% | 0.02% |
| Starting torque | 150% at 0.25 Hz | 200% at 0 Hz |
| Torque response time | <20 ms | <10 ms |
| Torque accuracy | 5% | 3% |
Figures apply to the indicated control mode. FVC requires compatible encoder feedback; motor characteristics, tuning and load conditions affect achieved performance.
PLC networks, encoder feedback and I/O options
| Interface / option | Model | Integration detail |
|---|---|---|
| RS485 Modbus RTU | Standard interface | Set address, baud rate, parity and drive command source |
| PROFINET | PD510PN1 | Optional network card |
| PROFIBUS-DP | PD510DP1 | Optional network card |
| Modbus TCP | PD510EN1 | Optional Ethernet card |
| EtherCAT | PD510EC1 | Optional network card |
| CANopen | PD510CAN1 | Optional network card |
| I/O expansion | PD510IO1 | 1 AI, 1 AO, 4 DI, 1 DO, 2 relays; PT100 / PT1000 / KTY84 |
| Incremental encoder | PD510PG1-TTL / HTL | TTL 5 V / HTL 24 V; 1:1 frequency output |
| Sine/cosine encoder | PD510PG2 | 5 V or 8 V supply; confirm the absolute encoder interface |
| Resolver | PD510PG3 | Transformation ratio 0.5 |
| Operator panels | Dual-display LED / LCD | Local operation; confirm remote-panel arrangement |
Specify the PLC model, network, motor and encoder signal when enquiring. Industrial networks use optional cards; they are not all built into the standard drive.
A replacement plan your team can check.
Changing a drive should start with an installation review. Send the complete existing part number and motor plate; we can propose a MAX510 rating and identify the wiring, panel and parameter changes.
| Existing equipment | Review before choosing MAX510 | Quotation scope |
|---|---|---|
| INVT / Delta VFDs | Continuous current, overload, control source and braking | Drive rating and required options |
| Danfoss / ABB / Siemens VFDs | Exact model, enclosure, feedback, PLC network and duty | Installation checks and integration requirements |
| OEM machine or new control panel | Load cycle, I/O list, dimensions, motor and network | Configured supply, drawings and support scope |
Brand names identify equipment being reviewed. Matching power alone does not establish identical dimensions, terminals, software or certifications.
For distributors & OEM partners
Discuss sample orders, repeat-order pricing, OEM branding, spare parts and technical support. Build your offer around a checked configuration and a confirmed delivery schedule.
Have an existing drive to replace?
Start with your company, phone and selected product. Our team can then review the existing model and application with you.
Real hardware. Practical application planning.
MAX510 in an industrial control cabinet
The project photograph shows MAX510 drives integrated into floor-standing control cabinets with door-mounted operator panels and local controls.
- Review cabinet ventilation, ambient temperature and service clearance.
- Define local/remote operation, interlocks and PLC interfaces.
- Confirm protection, reactor and braking requirements for the load.

| Application | Relevant MAX510 functions | Selection discussion |
|---|---|---|
| Pumps & water treatment | Process PID, analog feedback, flying start | Pump current, pressure/flow feedback and operating range |
| Fans & blowers | V/f or SVC, speed-tracking start, adjustable ramps | Load inertia, minimum speed and motor cooling |
| Conveyors, mixers & process machinery | Vector control, torque limit, 16-step speed, simple PLC | Starting torque, load cycle and sequence interlocks |
| Compressor packages | PID, motor autotuning, frequency references | Motor type, speed limits and control-system interface |
| Spindles & high-speed motors | High-speed motor configuration; output up to 600 Hz | Motor electrical data, pole count, bearing speed and tuning |
Applications describe selection possibilities; the final motor and machine requirements determine the supplied configuration.
Check the details behind your order.
Confirm the applicable coverage, support process and spare-parts arrangement in the quotation.
Agree the exact model, duty, option cards, braking hardware and cabinet scope.
Request the test documentation and certificates applicable to the selected model and destination market.
Plan motor-data setup, parameter backup, I/O checks and PLC communication before startup.
Specifications, functions and accessories.
Electrical ratings and operating functions
| Characteristic | Specification |
|---|---|
| Input frequency | 50 / 60 Hz, tolerance ±5% |
| Supply tolerance | Voltage fluctuation ±15%; voltage imbalance <3% |
| Output voltage | Three-phase, 0 to rated input voltage; error within ±3% |
| Output frequency | 0.00–600.00 Hz; resolution 0.01 Hz |
| Overload | G Normal Duty: 150% for 60 s; P Light Duty: 120% for 60 s |
| Switching frequency | 0.5–16 kHz; confirm the setting and applicable derating |
| Acceleration / deceleration | 0.0–30000 s; selectable curves and four ramp-time sets |
| Frequency commands | Keypad/digital, communications, analog and terminal pulse |
| Process & sequence functions | PID; simple PLC; 16-step speed; wobble frequency; fixed-length and counting |
| Motor & torque functions | Autotuning; two motor parameter sets; torque limiting; droop; field weakening |
| Continuity & diagnosis | Flying start; over/undervoltage stall protection; power-loss restart settings; three fault-history records |
| Motor configurations | Induction, synchronous, high-speed and spindle motor configurations; specify motor data before ordering |
Control terminals and protection
| Interface | Standard arrangement |
|---|---|
| Digital inputs | 5 bidirectional inputs; DI5 can be configured for a high-speed pulse input |
| Digital output | 1 output; high-speed pulse output optional |
| Analog I/O | 2 analog inputs and 1 analog output, voltage/current selection |
| Relay | 1 changeover relay; 250 VAC: >10 mA and <3 A; 30 VDC: >10 mA and <5 A |
| Auxiliary supplies | 10 V / 20 mA; 24 V / 200 mA |
| Protection | Overcurrent, over/undervoltage, overload, short circuit, overtemperature, phase loss, PID feedback, communication and external faults |
Terminal assignments and DIP-switch positions must match the wiring and selected command source. Use the manual supplied with the drive for commissioning.
Braking, reactors and cabinet options
| 380–480 V G rating | Braking arrangement | Reactor arrangement |
|---|---|---|
| 0.75–11 kW | Optional built-in braking unit | Review supply and motor-cable requirements |
| 15–22 kW | Built-in braking unit as standard | Review supply and motor-cable requirements |
| 30–110 kW | Optional built-in braking unit | DC reactor optional |
| 132–560 kW | External braking unit for the listed braking selections | Built-in DC reactor |
| 630–710 kW cabinet | Listed without braking; application review if required | Input AC reactor; optional output AC reactor |
Resistor resistance, thermal power and duty cycle must match the drive/braking unit and stopping duty. The full resistor tables are available in the catalog. For input/output reactors or filters, review cable length, motor insulation and site EMC requirements.
Environment, cooling and storage
| Condition | Limit / requirement |
|---|---|
| Installation | Indoor; avoid direct sunlight, corrosive or flammable gases, dust, oil mist, water and salt |
| Ambient temperature | −10°C to +50°C; above 40°C, derate output current by 1% per °C |
| Altitude | 0–2000 m; above 1000 m, derate by 1% per additional 100 m |
| Humidity | 0–95% RH, non-condensing |
| Vibration | Less than 5.9 m/s² (0.6 g) |
| Storage temperature | −20°C to +60°C |
| Protection / cooling | IP20 drive; forced air cooling. Confirm the complete cabinet enclosure separately. |
| Efficiency at rated load | ≤7.5 kW: ≥93%; 11–45 kW: ≥95%; ≥55 kW: ≥98% |
Designed for installation and service
A narrow book-style frame, organized terminals, expansion interfaces and accessible fan cover help panel builders arrange wiring and maintenance access. The independent air duct separates the heat-sink airflow from the electronics area.
Use overall and mounting dimensions together, and retain the required cooling and service clearances.

MAX510 selection & integration FAQ
Have another application question? Ask about MAX510
Which applications are a good fit for MAX510?
MAX510 is a high-performance vector VFD for industrial machinery, conveyors, mixers, fans, pumps and compressor systems. V/f, sensorless vector and feedback vector modes let the drive be matched to the load. For lifting, high-inertia or continuously regenerative loads, discuss the braking cycle and machine safety functions separately before selection.
How do I choose between G Normal Duty and P Light Duty?
Select using motor nameplate current and the actual load cycle. G Normal Duty is rated for 150% overload for 60 seconds; P Light Duty is rated for 120% for 60 seconds. For example, MAX510-4T-55G/75P-L identifies different 55 kW G and 75 kW P duties. The higher P power must not be used as the G rating for a constant-torque load. The selection table lists G-duty output current; confirm the P-duty current for your final configuration.
Can a 220 V MAX510 drive a 380 V motor?
The standard 220–240 V models provide three-phase 220–240 V-class output, not voltage boost to 380–480 V. A motor must be suitable for the output voltage and its winding connection must match. Check the motor plate before ordering. The 2S models use single-phase input; 2T models use three-phase input.
Does MAX510 need an encoder, and which PLC networks can I use?
Sensorless vector control works without an encoder. Feedback vector control needs a compatible encoder and PG interface. RS485 Modbus RTU is standard. PROFINET, PROFIBUS-DP, Modbus TCP, EtherCAT and CANopen use their corresponding optional cards. Specify the PLC, network and encoder signal before ordering so the hardware and configuration can be confirmed together.
Can MAX510 replace an INVT, Delta, Danfoss, ABB or Siemens VFD?
We can assess a MAX510 replacement against the exact existing model, motor and application. The review covers continuous current, overload, feedback, braking, dimensions, I/O and PLC communication. We identify the required panel and parameter changes before quotation; matching kW does not establish interchangeable terminals, mounting or software.
Do I need a braking resistor or an external braking unit?
The answer depends on the frame, ordered hardware and stopping duty. For 380–480 V units, a built-in braking unit is standard at 15–22 kW and optional at 0.75–11 kW and 30–110 kW. The 132–560 kW braking selections use an external unit. The 630–710 kW cabinet models are listed without braking; discuss an engineered arrangement if required. Supply inertia, stopping time and braking frequency for resistor selection.
What should I check if the drive trips or the motor will not run?
Record the fault code and operating condition first. For overvoltage during stopping, review deceleration time and braking duty. For no motor rotation, check the local/remote command source, run enable, active interlocks and frequency reference. For Modbus errors, check address, baud rate, parity, wiring and termination. Back up parameters before resetting. Electrical inspection must be performed by qualified personnel after isolation and verified discharge.
What are the lead time, warranty and distributor arrangements?
MAX510 is offered with a 24-month warranty. We confirm stock, production lead time and dispatch date against the exact model, option cards, cabinet requirements and quantity in the quotation. Distributors and OEMs can discuss sample orders, volume pricing, branding, spare parts and commissioning support. Use the distributor enquiry button to start with your company, contact name, phone and intended products.
Take the selection data with you.
For a 710 kW cabinet, model-specific drawing or network-card document, request the matching configuration documents with your enquiry.
Let’s match MAX510 to your requirement.
Start with your product enquiry.
Tell us your company and phone number, then select the products you need. Our team can confirm the motor data, options, quantity and delivery requirement with you.
- Drive selection and replacement review
- Network, encoder and cabinet options
- Quotation and confirmed dispatch estimate
Build your MAX510 product offering.
For distributors and OEM partners: discuss product selection, sample orders, commercial terms, spares and technical support.
Discuss a distributor partnership →
Prefer direct contact?
info@inomaxtechnology.com