MAX600 HVAC VFDs.
Control comfort. Manage water. Move air.
Dedicated fan and pump control for HVAC contractors, system integrators and distributors. Choose 220 V or 380–480 V models, with pressure PID, sleep/wake control and application functions for water and ventilation systems.
Simple enquiry • Product multi-select • Technical selection support

Choose the voltage. Check the current.
Start with the supply and motor nameplate current, then check load duty, installation temperature, enclosure and control requirements. The table gives model codes, current ratings and overall dimensions for initial selection.
| Input supply | Motor power range | Listed output current |
|---|---|---|
| 3-phase 380–480 V · T4 | G: 0.75–630 kW; P designations up to 710 kW | 2.1–1120 A at the listed G ratings |
| 1-phase 220 V · S2 | 0.75–2.2 kW | 5–11 A; 3-phase 220 V-class motor output |
| 3-phase 220 V · T2 | 0.4–75 kW | 3.5–304 A; 3-phase 220 V-class motor output |
| Motor kW | Model | Input A | Output A | H × W × D, mm |
|---|---|---|---|---|
| 0.75 | MAX600-R75GT4 | 3.4 | 2.1 | 152 × 91 × 123 |
| 1.5 | MAX600-1R5GT4 | 5 | 3.8 | 152 × 91 × 123 |
| 2.2 | MAX600-2R2GT4 | 5.8 | 5.1 | 152 × 91 × 123 |
| 3.7 | MAX600-3R7GT4 | 10.5 | 9 | 185 × 118 × 167 |
| 5.5 | MAX600-5R5G/7R5PT4 | 14.6 | 13 | 185 × 118 × 187 |
| 7.5 | MAX600-7R5G/011PT4 | 20.5 | 17 | 247 × 160 × 190 |
| 11 | MAX600-011G/015PT4 | 26 | 25 | 247 × 160 × 190 |
| 15 | MAX600-015G/018PT4 | 35 | 32 | 320 × 220 × 205 |
| 18.5 | MAX600-018G/022PT4 | 38.5 | 37 | 320 × 220 × 205 |
| 22 | MAX600-022/030PGT4 | 46.5 | 45 | 320 × 220 × 205 |
| 30 | MAX600-030G/037PT4 | 62 | 60 | 432 × 255 × 235 |
| 37 | MAX600-037G/045PT4 | 76 | 75 | 432 × 255 × 235 |
| 45 | MAX600-045G/055PT4 | 92 | 91 | 453 × 275 × 235 |
| 55 | MAX600-055G/075PT4 | 113 | 112 | 518 × 300 × 260 |
| 75 | MAX600-075G/090PT4 | 157 | 150 | 518 × 300 × 260 |
| 90 | MAX600-090G/110PT4 | 180 | 176 | 620 × 390 × 300 |
| 110 | MAX600-110G/132PT4 | 214 | 210 | 620 × 390 × 300 |
| 132 | MAX600-132G/160PT4 | 256 | 253 | 620 × 390 × 300 |
| 160 | MAX600-160G/185PT4 | 307 | 304 | 780 × 480 × 360 |
| 185 | MAX600-185G/200PT4 | 340 | 335 | 1274 × 480 × 361 |
| 200 | MAX600-200G/220PT4 | 385 | 377 | 1274 × 480 × 361 |
| 220 | MAX600-220G/250PT4 | 430 | 426 | 1274 × 480 × 361 |
| 250 | MAX600-250G/280PT4 | 468 | 465 | 1274 × 480 × 361 |
| 280 | MAX600-280G/315PT4 | 525 | 520 | 1320 × 650 × 418 |
| 315 | MAX600-315G/355PT4 | 590 | 585 | 1320 × 650 × 418 |
| 355 | MAX600-355G/400PT4 | 665 | 650 | 1720 × 800 × 490 |
| 400 | MAX600-400G/450PT4 | 785 | 725 | 1720 × 800 × 490 |
| 450 | MAX600-450G/500PT4 | 883 | 820 | 1720 × 800 × 490 |
| 500 | MAX600-500G/560PT4 | 1000 | 930 | 1720 × 800 × 490 |
| 560 | MAX600-560G/630PT4 | 1100 | 1080 | 1850 × 1060 × 500 |
| 630 | MAX600-630G/710PT4 | 1200 | 1120 | 1850 × 1060 × 500 |
| 0.75 | MAX600-R75GS2 | 8.2 | 5 | 152 × 91 × 123 |
| 1.5 | MAX600-1R5GS2 | 14 | 7 | 152 × 91 × 123 |
| 2.2 | MAX600-2R2GS2 | 23 | 11 | 152 × 91 × 123 |
| 0.4 | MAX600-0R4GT2 | 3.4 | 3.5 | 152 × 91 × 123 |
| 0.75 | MAX600-R75GT2 | 5 | 5 | 152 × 91 × 123 |
| 1.5 | MAX600-1R5GT2 | 5.8 | 7 | 152 × 91 × 123 |
| 2.2 | MAX600-2R2GT2 | 10.5 | 11 | 152 × 91 × 123 |
| 3.7 | MAX600-3R7GT2 | 14.6 | 17 | 185 × 118 × 187 |
| 5.5 | MAX600-5R5GT2 | 26 | 25 | 247 × 160 × 190 |
| 7.5 | MAX600-7R5GT2 | 35 | 32 | 320 × 220 × 205 |
| 11 | MAX600-011GT2 | 46.5 | 45 | 320 × 220 × 205 |
| 15 | MAX600-015GT2 | 62 | 60 | 432 × 255 × 235 |
| 18.5 | MAX600-018GT2 | 76 | 75 | 432 × 255 × 235 |
| 22 | MAX600-022GT2 | 92 | 91 | 453 × 275 × 235 |
| 30 | MAX600-030GT2 | 113 | 112 | 518 × 300 × 260 |
| 37 | MAX600-037GT2 | 157 | 150 | 518 × 300 × 260 |
| 45 | MAX600-045GT2 | 180 | 176 | 620 × 390 × 300 |
| 55 | MAX600-055GT2 | 214 | 210 | 620 × 390 × 300 |
| 75 | MAX600-075GT2 | 307 | 304 | 780 × 480 × 360 |
No model matches this filter. Select another power band or request sizing support.
T4 dual-rated model codes show G / P power designations. The kW and current columns refer to the listed G rating, not the higher P designation. Confirm the required P current and overload with the quotation. H = height, W = width, D = depth; allow additional installation and service clearances.
HVAC functions that solve everyday operating problems.
Pressure and process PID
PID1 adjusts drive frequency from the setpoint and process feedback. PID2 provides an auxiliary analog output for another control function.
Automatic sleep & wake-up
Enter sleep when configured low-demand conditions persist. Restart when the wake-up conditions are met, using adjustable thresholds and delays.
Soft pipe filling
Fill an empty pipe at a controlled frequency before transferring to PID regulation, helping limit water hammer during startup.
Multi-pump coordination
Stage pumps as demand changes, rotate the controlled pump and configure a changeover frequency to help limit pressure dips.
Fan restart and resonance avoidance
Speed-tracking restart matches a rotating motor before resuming drive operation. Three skip-frequency settings help avoid sustained operation in resonance bands.
Light-load energy control
Automatic output-voltage adjustment supports efficient motor operation at light load. Linear or S-curve ramps tailor acceleration and deceleration to the system.
Multi-pump control needs optional relay expansion, external contactors and equal-rated motors; it is not recommended at 30 kW and above. For asynchronous motors, speed tracking is not supported in SVC 0 mode. Final settings must match the motor and equipment.
Pump protection, cleaning and maintenance functions
| Function | What it does | Configuration to confirm |
|---|---|---|
| Pump cleaning | Forward → stop → reverse → stop sequence, triggered from the stopped state | Use only where the pump permits reverse rotation |
| Pipe-burst detection | Stops after configured detection conditions persist for the selected delay | Setpoint, detection level and delay |
| Frost protection | Runs the motor at a preset frequency below the temperature threshold | Connected PT100 / PT1000 / KTY84 sensor and function setup |
| Condensation protection | Externally triggered DC injection warms the stopped motor in a 40-second cycle | External trigger and motor-specific setup |
| Underload pre-alarm | Signals when output current remains below a configured threshold | Current threshold and time delay |
| Pump maintenance mode | Excludes a selected pump from the multi-pump sequence | Sequence exclusion is not electrical isolation; isolate power before servicing |
Ventilation, commissioning and diagnostic functions
| Function | Application value |
|---|---|
| 16 preset speed steps | Select speed references for different operating conditions |
| Motor autotuning | Rotary or static identification; static tuning is available when the motor cannot be disconnected from its load |
| Adjustable DC braking | Configurable start frequency, delay, current and duration; stop-braking time 0–50 s |
| Fault history | View the present fault and five previous fault types |
| Automatic voltage regulation | Reduces the effect of DC-bus fluctuation on output voltage; it is not backup power |
| Fire-mode operation | External activation, preset frequency and selectable direction for engineered emergency ventilation |
Fire-mode selection: Mode 1 prioritizes continued operation until drive damage prevents running. Mode 2 retains the fault stops specified in the manual. Both require an engineered system review; drive functionality alone does not certify a smoke-control system. Fire mode changes normal fault handling and can damage equipment. The manual excludes warranty repair when fire-mode operation reaches five minutes.
Connect the drive to the way your building operates.
| Interface | MAX600 configuration | What to tell us |
|---|---|---|
| BMS / PLC communication | Standard RS485 Modbus RTU | Controller model, addresses, speed / status points and network topology |
| Analog control | 2 analog inputs and 2 analog outputs; voltage/current configuration | Pressure, temperature or flow sensor signal and scaling |
| Digital control | Programmable inputs, high-speed pulse input and shared input/output function | Run enable, interlocks, local/remote commands and feedback |
| Relay outputs | 2 programmable relays; expansion required for multi-pump arrangements | Run, fault, pump sequencing and contactor logic |
| Operator panel | Keypad operation and external keypad connection | Door mounting, cable arrangement and local/remote operating method |
For BACnet or another building-control protocol, specify the required network so the matching interface or gateway can be confirmed. Do not assume an additional protocol is supplied as standard.
A practical replacement review for your team.
Use MAX600 as a candidate for an HVAC drive replacement or a new fan-and-pump product offering. We compare the exact installed model and application before proposing an equivalent rating and the necessary changes.
| Existing platform / requirement | Replacement review |
|---|---|
| ABB ACH, Danfoss VLT HVAC Drive, Schneider Altivar HVAC and other HVAC VFDs | Exact part number, continuous current, overload duty, enclosure and compliance |
| BMS and control cabinet | Modbus / other network, analog scaling, terminals, interlocks and alarms |
| Mechanical fit and installation | Overall and mounting dimensions, airflow, clearances, cable entry and protection |
| Fan / pump operating logic | PID, sleep/wake, flying start, multi-pump switching and emergency ventilation |
| Commissioning and commercial scope | Parameter mapping, accessories, test requirements, spares, quantity and delivery |
Matching kW does not establish interchangeable terminals, dimensions, parameter files or approvals. Compatibility is confirmed for the actual model and application.
Have an existing drive to replace?
Start with your company, phone and selected product. Our team can then check the current drive model and motor plate with you.
Build your HVAC drive offering.
Discuss sample orders, project pricing, OEM requirements, spare parts and technical support for repeat installations.
From building comfort to dependable water flow.
Fans & air handling
Supply/extract fans, air-handling units and cooling-tower fans. Match pressure or temperature demand while reviewing minimum speed, motor cooling and resonance bands.
Pumps & circulation
Chilled-water loops, heating circulation and pressure-boosting systems. Configure PID, soft filling and sleep/wake around the hydraulic system.
Water & process systems
Water treatment, pumping stations and utility equipment. Review monitoring, pump-cleaning compatibility, sensor feedback and operational redundancy.
Prepare a project-ready offer.
- Motor plate, supply and duty point
- Fan / pump operating range and required sensors
- Ambient temperature, altitude and enclosure
- BMS points, cabinet scope and commissioning needs
- Quantity, delivery destination and target date
Review relevant application experience.
INOMAX supports water-system and industrial drive applications. Ask for a reference relevant to your equipment, rating and control requirements, together with the proposed MAX600 configuration.
Project-specific energy savings depend on the actual duty profile, hydraulic or airflow conditions and the comparison baseline.
Check the configuration behind the quotation.
Agreed coverage and service terms apply. Review the specific fire-mode exclusion before configuring emergency operation.
Agree the rating, enclosure, interfaces, relay expansion and supplied cabinet hardware before ordering.
Request certificates and test documents applicable to the selected product and destination market.
Plan motor data, PID tuning, sensor scaling, network mapping and parameter backup with the application team.
Technical specifications and accessories.
Electrical ratings and motor-control performance
| Characteristic | Specification / selection point |
|---|---|
| Input frequency | 50 / 60 Hz; operating range 47–63 Hz |
| Voltage tolerance | −15% to +10% of the selected input rating |
| Output frequency | 0–400 Hz; set motor and equipment speed limits appropriately |
| Control modes | Space voltage vector control and sensorless vector control (SVC) |
| Motor compatibility | Asynchronous and synchronous motors; verify the motor data and selected mode |
| SVC speed range | Asynchronous motor: 1:200; synchronous motor: 1:20 |
| SVC speed performance | Accuracy ±0.2%; fluctuation ±0.3% |
| SVC torque performance | Response <20 ms; control accuracy ±10% |
| Overload selection | Confirm the required overload current and duration for the chosen model and duty with the quotation |
| Frequency references | Digital, analog, pulse, multi-step speed, simple PLC, PID and communication; switchable / combined sources |
| Protection | Overcurrent, overvoltage, undervoltage, overtemperature, phase loss and overload functions |
I/O, EMC and installation options
| Item | Arrangement |
|---|---|
| Analog inputs / outputs | AI1 and AI2; AO0 and AO1. Check signal ranges and jumper settings against the supplied control board |
| Relay outputs | RO1 and RO2: NO / NC / common. Contact rating 3 A at 250 VAC; 1 A at 30 VDC |
| Digital / pulse interface | Programmable inputs and high-speed pulse input up to 50 kHz; shared input/output selected by jumper |
| Keypad | Standard LED keypad; external keypad port |
| C3 EMC filter | Optional built-in filter at 1.5–132 kW; built-in filter standard at 160 kW and above |
| Multi-pump options | Relay expansion and interlocked external contactors; equal-rated motors |
| Reactor / filter selection | Assess supply quality, cable length, motor insulation and site EMC requirements |
| Mounting | Wall- and floor-mounted configurations; confirm the selected frame and installation drawing |
Environment, enclosure and storage
| Condition | Requirement |
|---|---|
| Ambient temperature | −10°C to +50°C; derate above +40°C |
| Installation altitude | Below 1000 m as the standard application condition; request selection review above this altitude |
| Humidity | Less than 95% RH, non-condensing |
| Vibration | Less than 5.9 m/s² (0.6 g) |
| Storage temperature | −20°C to +60°C |
| Protection / cooling | Standard IP20, forced-air cooling; optional IP55 / IP65 configurations subject to model confirmation |
| Environment | Indoor installation; protect from direct sunlight, corrosive or flammable gases, conductive dust, oil mist, dripping water and salt |
| Cabinet planning | Provide cooling airflow, service access and suitable protection for the complete installation |
MAX600 HVAC drive FAQ
Need help with a particular fan, pump or BMS? Ask about MAX600
Which HVAC applications is MAX600 designed for?
MAX600 is a dedicated HVAC variable frequency drive for ventilation fans, air-handling units, cooling-tower fans, chilled-water and circulation pumps, pressure-boosting systems and water-treatment equipment. Its application functions include PID regulation, sleep and wake-up, soft pipe filling, pump sequencing and fan restart. Send the motor current, supply and operating range so we can confirm the right configuration.
How do I select the voltage, power and current rating?
First match the input supply: single-phase 220 V, three-phase 220 V or three-phase 380–480 V. Then select by motor nameplate current, duty cycle, ambient conditions and required enclosure. The 380–480 V range lists 0.75–630 kW G models, with light-duty P designations up to 710 kW. The table current belongs to the listed G rating; confirm the corresponding P current and overload requirement before ordering. A standard 220 V unit does not boost its output to 400 V.
Can MAX600 control pressure without a separate PID controller?
Yes. The dedicated PID1 controller adjusts drive frequency using the configured setpoint and sensor feedback. PID2 provides an auxiliary analog output. Match the pressure or process sensor signal, scaling, control direction and fault response to the installation. Sleep and wake thresholds, delay times and soft-fill settings can then be configured to suit demand.
Can one MAX600 control several pumps?
The multi-pump function supports systems with up to four pumps. It requires the appropriate relay expansion, external contactors, interlocking and commissioning; the connected motors must have the same rated power. Pump addition/removal, rotation, maintenance exclusion and controlled changeover are configurable. This multi-pump function is not recommended for drives rated 30 kW and above. For larger pump groups, ask us to review a drive-per-pump or engineered control arrangement.
Can MAX600 connect to our BMS or PLC?
RS485 Modbus RTU is the standard communication route. Analog references, sensor inputs, programmable relays and digital controls are also available. Provide the BMS or PLC model, protocol and points list so we can check run commands, speed references, status and fault mapping. If the project requires BACnet or another network, have the interface or gateway confirmed in the quotation; do not assume it is built in.
How does MAX600 help with low demand, water hammer and blocked pumps?
Sleep/wake control can stop unnecessary low-demand running and restart when configured conditions are met. Soft filling brings an empty pipe to the configured threshold before PID control takes over. A forward-stop-reverse-stop cleaning routine is available for pumps that permit reverse rotation. Pipe-burst detection, underload monitoring and frost protection require suitable thresholds, delay settings and, where relevant, a temperature sensor.
Can MAX600 replace an ABB ACH, Danfoss VLT HVAC or Schneider HVAC drive?
We can assess MAX600 against an exact existing model from ABB ACH, Danfoss VLT HVAC Drive, Schneider Altivar HVAC or another platform. The comparison checks continuous current, overload duty, motor type, enclosure, EMC, dimensions, BMS communication, I/O and emergency-ventilation requirements. Mounting, terminals and parameter files are not assumed to be interchangeable. Send the installed drive model and motor plate for a replacement review.
What are the delivery time, warranty and distributor options?
Stock, production and dispatch dates are confirmed for the exact rating, enclosure, options and quantity. Standard orders are offered with a 24-month warranty subject to agreed terms. Fire-mode operation has a specific exclusion: the manual states that warranty repair is not granted when fire-mode running reaches five minutes. Distributors and OEMs can discuss sample orders, project pricing, branding, spare parts and commissioning support through the distributor enquiry button.
Keep the selection data close.
Request configuration-specific drawings, option details and commissioning documents with your quotation.
Let’s match MAX600 to your HVAC requirement.
Start with a simple enquiry.
Enter your company and phone number, then select the products you need. We can confirm the motor data, application and delivery requirements with you.
- Fan and pump drive selection
- BMS and replacement review
- Quotation and confirmed dispatch estimate
Become an INOMAX distributor.
Discuss MAX600 product selection, sample orders, project pricing, OEM requirements, spares and technical support.
Discuss a distributor partnership →
Prefer direct contact?
info@inomaxtechnology.com