Introduction to INOMAX Medium- and High-Voltage Soft Starters:
The INOMAX MAX-MVSS series high-voltage solid-state soft starter is designed to solve the problems of electrical shock and mechanical shock during starting process of medium and high voltage AC motors. It uses series-connected high-voltage thyristors and fully digital control.
The control of the voltage applied to the motor by means of adjustments to the firing angle of thyristors allows the soft-starter to start and stop an electric motor smoothly, also allowing the reduction of impacts of inrush current on the power supply and impacts of mechanical shocks on the load and the coupling. Thus, it is possible to eliminate the inrush current to the power supply and the mechanical shocks for the load up to the couplings.

Voltage Range
2 kV
2.4 kV
3 kV
3.3 kV
4.16 kV
6 kV
6.6 kV
10 kV
11 kV
13.8 kV
15 kV
Power Range
100 kW-50000 kW
150 hp-75000 hp
Available Protections
Undercurrent/overcurrent and current imbalance, under/overvoltage and voltage imbalance, under/overtorque and active overpower, phase loss, inverted phase sequence, power arm overtemperature, motor overload, motor overtemperature (optional), external fault, ground fault by voltage or by current, power arm faults, power contactor faults, control board faults, communication fault of the HMI and between control boards, communication network faults, programming error.
Advantages
■ 6 preprogrammed smooth starting and stopping modes use vector control and direct torque control concepts, based on technologies developed for vector frequency inverters, to provide a linear speed ramp according to the load type applied to the motor;
■ User-friendly configuration and operation;
■ The guided startup function provides a minimal programming sequence to begin operation;
■ Motor protection built into the standard cabinet (eliminating the need for extra protection relays);
■ Ground Fault Protection – Standard;
■ Input sectioning/protection integrated (line contactor or circuit breaker); ■ Heavy-duty design up to 50 °C ambient temperature;
■ Reduction of power demand during starting;
■ Reduction of inrush current on the power supply during starting; ■ Reduction of mechanical shocks during starting;
■ Reduction of mechanical stress on the load and on the coupling;
■ Increases the design life of the motor, mechanical and electrical systems;
■ Standard/customized project according to customer requirements following the application characteristics.
Main Characteristics
■ Power Range: 300 hp up to 16.300 hp (235 kW up to 12.200 kW);
■ Motor Voltage: 2.3 kV up to 13.8 kV;
■ Output current: 70 A, 125 A, 180 A, 250 A, 300 A, 360 A, 400 A, 500 A and 600 A (other power / output currents – please consult);
■ Main input: switch + contactor (fixed) / circuit breaker (withdrawable) (medium voltage fuses for the input protection, for the switch + contactor configuration);
■ Integrated bypass: contactor (fixed) / circuit breaker (fixed) (main and bypass contactors/circuit breakers: vacuum insulated);
■ Main and bypass vacuum contactors/circuit breakers are able to perform DOL starting;
■ Protection degree: IP41, IP54 and NEMA 12 (option for outdoor solution – please consult);
■ Complete isolation between LV (control) and MV (power) compartments, communicating via fiber optics;
■ The power supply can be interconnected between MAX-MVSS units using busbars;
■ Frontal access (no need for rear access);
■ Easy installation and suitable for retrofits;
■ 310.000 hours MTBF; 8 hours MTTR;
■ Ground Fault Protection by Voltage or by Current;
■ Active protection for the motor in DOL mode;
■ 6 start modes: torque control, pump control, current ramp, voltage ramp, current limit, direct-on-line starting;
■ Operating interface (HMI) with graphic LCD;
Production Line:

Internal Product Details

Some of Our OEM Customers